5800W Dual Fuel Portable Inverter Generator Electric Start With CO Alert
SKU: SUA5800iED
Barcode: 850055834873
- A-iPower dual fuel generator offers the choice of operating with gasoline, propane, or both with Fuel Sense Technology
- 2.6 Gallon Tank, up to 12 Hours Runtime
- 15-Hour Runtime with 20 lbs. Propane Cylinder
- Extended 27-Hour Runtime (No Refueling) with Fuel Sense Technology
- 5800 Starting / 4500 Running Watts (Gas)
- 5200 Starting / 4000 Running Watts (Propane)
- 224cc OHV 4-Cycle Engine with Low-Effort Recoil & One-Touch Electric Start
- Light Weight Technology: Just 87.5 lbs.
- Pure Sine Wave with <3% THD with All-Copper Alternator
- Parallel Ready
- As low as 63dB Noise Level
Multi-Featured Control Panel with LED - Mobility Kit
- Low Effort Recoil or Electric Start
- Free Shipping
- Free Returns Within 30 days
Couldn't load pickup availability
Description
Description
This EPA-Certified A-iPower dual fuel generator offers the choice of operating with gasoline, propane, or both with Fuel Sense Technology. Through its 2.6-gallon tank, the unit provides up to 12 hours of runtime on gasoline, 15 hours of runtime with a 20-pound propane cylinder, and an extended 27-hour runtime, with no refueling, through Fuel Sense Technology.
Offering 5800 Starting / 4500 Running Watts on gas and 5200 starting / 4000 Running Watts on propane, the 224cc OHV 4-Cycle Engine has a low-effort recoil and one-touch electric start. Featuring Pure Sine Wave with <3% THD and an all-copper alternator, the parallel-ready unit is only 87.5 pounds and operates at decibel levels as low as 63dB.
The inverter has a multi-featured control panel with LED, and it is ANSI/PGMA G300 Compliant with CO sensor shutdown.
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
5800W Dual Fuel Portable Inverter Generator Electric Start With CO Alert






INTELLIGENT CONTROL HUB


✅ Key Features
Fuel Sense
Fuel Sense Technology, the generator prioritizes propane (LPG) and automatically transitions to gasoline when needed — delivering extended runtime without manual.
LED LIGHT
Easily navigate and monitor the control panel in low-light or nighttime conditions, ensuring clear visibility, quick operation, and added convenience wherever you use the generator.
100% COPPER WINDING
Equipped with a premium brushless alternator featuring 100% copper windings for improved efficiency, stable power output, and extended service life.
ECO MODE(Low Idle)
Eco Mode automatically adjusts engine speed based on load demand, reducing fuel consumption and noise while maintaining consistent power output.
CO-MINDER®
CO-MINDER® continuously monitors carbon monoxide levels and automatically shuts down the generator if unsafe levels are detected for enhanced safety.
SUPER QUIET
Fully enclosed design delivers quiet performance — 52 dB in optimal conditions, ~62 dB under standardized testing, ideal for campsites and residential use.
USB CHARGING
Dual USB ports (USB-A 3.6A and USB-C 3A) provide convenient power for charging phones, tablets, and other small electronic devices.
PARALLEL READY
Parallel-ready design allows connection to a second Ai-Power inverter generator using an optional parallel kit to increase total power output.
POWER WHERE YOU NEED IT
Reliable, Quiet, and Portable Inverter Generator for On-the-Go Energy.








WHAT'S IN THE BOX?


| SPECIFICATIONS | |
|---|---|
| Model number | SUA5800iED |
| OUTPUT | |
| Running Watts(gas) | 4500W |
| Starting Watts(gas) | 5800W |
| Running Watts(lpg) | 4000W |
| Starting Watts(lpg) | 5200W |
| AC Voltage | 120V / 240V |
| Frequency | 60Hz |
| Decibels | 63 dBA @ 1/2 Load – 21' / 7m |
| Run Time @ 25% Load(gas) | 11 hours |
| Run Time @ 50% Load(gas) | 8 hours |
| Run Time @ 100% Load(gas) | 4 hours |
| Runtime @ 25% Load(gas+lpg) | 27 Hrs via Fuel Sense |
| THD @ Full Load | < 3% |
| Automatic Voltage Regulator | Yes |
| ENGINE | |
| Engine (OHV) | Senci |
| Displacement (cc) | 224cc |
| Engine Type | Single cylinder, 4-Stroke, OHV, Air Cooled |
| Starting Type | Recoil / Electric Start (Battery Included) |
| Fuel Type | Gasoline / Propane |
| Tank (Gas) | 2.6 gal. / 10L |
| Recommended Oil | SAE 10W-30 |
| Engine Oil Capacity (Qt. / L) | 0.74 qt. (0.7 L) |
| Output Speed (RPM) | 2600-3800RPM |
| Muffler with USDA Spark Arrestor | Yes |
| Low-Oil Shutdown | Automatic |
| Lubrication | Splash |
| CONTROL PANEL | |
| Rated Amperage(AMP) | 37.5/33.3 |
| Phase | Single |
| Circuit Breakers | Yes |
| Rubber Outlet Dust Covers | Yes |
| TT-30R AC120V/30A Port | 1 |
| 5-20R 120V 20A Port | 2 |
| DC USB-A 3.6A Port | 1 |
| DC USB-C 3A Port | 1 |
| Data Center | Voltage, Frequency, Hours, Power, Fuel Bar, Output Ready/ Overload/Low Oil indicators Low Idle and Reset Buttons |
| Low Idle Mode | Yes |
| Parallel Output | Yes |
| Neutral Bonded to Frame | Yes |
| CO Monitor | Yes |
| Illuminated Control Panel | Yes |
| Fuel Sense | Yes - Automatic Fuel Selection Technology |
| CERTIFICATIONS | |
|---|---|
| EPA Certified | Yes |
| PGMA Compliant | Yes |
| TRANSPORTATION | |
| Mobility Kit | Yes - Built-In & Telescopic |
| Wheel | Yes - Factory Assembled |
| PACKAGING | |
| UPC | 850055834873 |
| Mobility Kit | Yes - Built-in & Telescopic |
| Net Weight | 87.5 lbs / 39.6 kg |
| Gross Weight | 100.3 Ibs / 45.5 kg |
| Assembly Dimension | 21.3 x 15.6 x 19.9 in / 54.1 x 39.6 x 50.5 cm |
| Packing Dimension | 27.0 x 18.5 x 21.9 in / 68.5 x 47.0 x 55.5 cm | Included | Oil, Funnel, Manual, Quick Start Guide, Tool Kit, Battery Float Charger, LPG Hose with Regulator, Fuel Sense Technology |
| GENERAL | |
| Warranty | 3 Year |
Unboxing & Operation Video
Maintenance Video
Video content is being prepared and will be updated soon.
Stay tuned for more exciting content!
Latest Technology
1、WHAT IS FUEL SENSE?
This generator is equipped with Fuel Sense Technology, which automatically switches the fuel intake between gasoline and propane (LPG) to extend runtime.
Propane is the prioritized fuel, meaning the generator will begin using propane as soon as the propane cylinder valve is opened.
The generator will automatically switch to gasoline if:
There is insufficient propane remaining in the cylinder, or
The propane cylinder valve is closed.
Safety Q&A
1、Where should I place the generator during operation?
Always operate the generator outdoors only. Keep it at least 20 feet (6 m) away from doors, windows, and vents, and at least 5 feet (1.5 m) away from any combustible materials. Place it on a dry, stable surface under a protective cover or canopy to shield it from the weather.
2、What should I know before refueling a generator?
Always turn off the generator and let it cool down completely before refueling.
Use clean, fresh fuel of the recommended grade.
Never refuel while the generator is running or hot, as this may cause fire or explosion.
3、Where should I safely store a generator when not in use?
Store the generator in a cool, dry, and well-ventilated location. Make sure the air vents are not blocked and that it is kept away from any flammable materials.
4、How do I safely transport a generator?
Before transporting, turn off the unit, drain the fuel tank, and disconnect the spark plug. Keep the generator upright during transport, ensure ventilation openings are not blocked, and avoid exposure to heat or moisture.
Setup/Startup
1、How do I connect the generator battery? (For models with electric start)
When you first receive the generator, the negative battery cable is usually disconnected to prevent discharge during storage.
- Locate the negative cable near the top or rear of the battery.
- Attach the loose end of the negative cable to the negative terminal post of the battery and tighten securely with a bolt.
- ⚠ Caution: Avoid touching both the battery terminal and the generator frame with tools or metal objects at the same time to prevent short circuits.
2、What type of engine oil should I use?
Initial use (break-in period): SAE 30, 10W-30, or 5W-30 mineral oil is recommended.
After break-in: You may use either mineral oil or full synthetic oil.
High temperatures (above 95°F / 35°C): 10W-40 is recommended.
3、What type of gasoline should I use?
Use unleaded gasoline with an octane rating of 87 or higher, and with ethanol content of no more than 10% (E10).
⚠ Tip: Lower ethanol content helps extend the life of the carburetor, fuel system, and seals.
4、How do I add fuel and check the oil for the first time?
Before the first startup, fill with the recommended engine oil.
Check the dipstick and ensure the oil level is within the marked range.
When adding oil or fuel, avoid spills, keep away from open flames, and use a dedicated oil/fuel container for safety.
5、How do I start the generator with recoil (pull) start? - Set the breaker and master control switch to OFF.
- Select the fuel type:
Gasoline: Open the gasoline valve → Turn the fuel selector to Gasoline.
Propane: Close the gasoline valve → Turn the fuel selector to Propane → Connect the propane tank and open the valve. - Switch the battery to ON (or “RUN” on some models).
- Pull the recoil cord: Pull slowly until resistance is felt, then pull sharply. Repeat if necessary until the engine starts
6、How do I use the electric start function?
Ensure the battery is properly connected and charged.
Set the fuel switch to the correct position.Turn the start switch to START.
Once the engine starts, release the switch and let it return to RUN/ON.
7、Does the generator need to warm up?
Yes. After starting, let the engine run idle for 1–3 minutes to allow the oil to circulate fully before applying a load.
8、How do I safely connect electrical loads?
Start the generator before connecting any appliances.
Connect higher-wattage devices first (e.g., refrigerator, air conditioner), then smaller devices.
Do not exceed the rated wattage capacity of the generator.
9、How do I start the generator in cold weather?
Use engine oil suitable for low temperatures (e.g., 5W-30).Place the generator in a warmer environment or use an engine block heater if available.Expect longer starting times in freezing conditions — this is normal.tent goes here.
Maintenance
1、How do I change the generator oil?
- Place the generator on a level surface.
- Locate the oil drain bolt at the bottom lip of the crankcase and place a container underneath.
- Use a 12mm wrench to remove the drain bolt and allow the oil to drain completely.
- Reinstall the bolt, remove the oil filler cap, and refill with oil until it reaches the thread level of the cap.
Tip: If the generator is on a flat surface, excess oil will naturally overflow before it is overfilled.
2、How do I drain fuel from the tank? - Turn the fuel valve to the OFF position.
- Place a container under the fuel 3. filter cup (below the valve).
- Remove the cup and turn the valve to ON to drain fuel completely.
Reinstall the fuel filter cup.
3、How should I prepare my generator for long-term storage?
Turn the circuit breaker OFF and run the generator for 3–5 minutes.
Switch the fuel valve to OFF and let the engine run until it shuts down.
Turn the engine/battery switch to OFF.
Drain remaining fuel from the tank and carburetor.
Remove the spark plug, add 2 tablespoons of 10W-30 oil into the cylinder, and pull the recoil starter a few times to lubricate.Reinstall the plug.
Disconnect and remove the battery, then maintain it with a trickle charger.
Store the generator in a cool, dry, and well-ventilated location.
4、How do I maintain the generator battery?
Generator batteries can lose charge within 3–6 months of storage.
Disconnect the battery when not in use.
Use a 12V SLA-compatible trickle charger to keep it charged.
Avoid exposing the battery to extreme heat or cold.
5、How often should I perform generator maintenance?
Before each use: Check fuel level, engine oil, and air filter. Every 50–100 hours of operation: Change engine oil, clean the spark plug, and service the air filter. Long-term storage: Drain fuel completely and store the generator properly.
6、Do I need to replace the air filter, and how often?
Yes. The air filter should be cleaned every 25 hours of use and replaced every 100–150 hours, or more often in dusty conditions.
7、When should I replace the spark plug?
Inspect the spark plug every 100 hours of operation. Replace it if it shows wear, buildup, or damage.
8、How do I prevent stale fuel from damaging the engine?
If the generator will not be used for more than 30 days, add a fuel stabilizer to fresh gasoline or drain the fuel system completely.
How to Contact Us for Further Assistance:
Phone Support: Connect directly with our knowledgeable customer service team at 855-888-3598 for immediate assistance.
Email Support: Send us an email with your inquiry, and our support team will respond promptly.
Live Chat: Use our real-time chat feature to get instant answers to your questions.
SUA5800iED Manual
SUA5800iED Spec Sheet
SUA5800iED Quick Start Guide
-
-
-
-
-
No reviews found
No questions found
Your cart
(0)
Order note
Coupon
Product Comparison
| Description |
| Price |
| Vendor |
| Type |
| Running Watts |
| Starting Watts |
| Run Time |
| Noise Level |
| Start Type |
| This EPA-Certified A-iPower dual fuel generator offers the choice of operating with gasoline, propane, or both with Fuel Sense Technology. Through its 2.6-gallon tank, the unit provides up to 12 hours of runtime on gasoline, 15 hours of runtime with a 20-pound propane cylinder, and an extended 27-hour runtime, with no refueling, through Fuel Sense Technology. Offering 5800 Starting / 4500 Running Watts on gas and 5200 starting / 4000 Running Watts on propane, the 224cc OHV 4-Cycle Engine has a low-effort recoil and one-touch electric start. Featuring Pure Sine Wave with <3% THD and an all-copper alternator, the parallel-ready unit is only 87.5 pounds and operates at decibel levels as low as 63dB. The inverter has a multi-featured control panel with LED, and it is ANSI/PGMA G300 Compliant with CO sensor shutdown. | Regular price
Sale price
$899.99 USD
Regular price
Unit price
/per
| A-iPower | Dual Fuel Inverter | 4500 | 5800 | 12 | 63 | Recoil, Electric |
Choose your option
Vendor: A-iPower
Type: Dual Fuel Inverter
- Modern
- Eco-certified
- Warranty
Hurry up, only 18 items left in stock.
This EPA-Certified A-iPower dual fuel generator offers the choice of operating with gasoline, propane, or both with Fuel Sense Technology. Through its 2.6-gallon tank, the unit provides up to 12 hours of runtime on gasoline, 15 hours of runtime with a 20-pound propane cylinder, and an extended 27-hour runtime, with no refueling, through Fuel Sense Technology.
Offering 5800 Starting / 4500 Running Watts on gas and 5200 starting / 4000 Running Watts on propane, the 224cc OHV 4-Cycle Engine has a low-effort recoil and one-touch electric start. Featuring Pure Sine Wave with <3% THD and an all-copper alternator, the parallel-ready unit is only 87.5 pounds and operates at decibel levels as low as 63dB.
The inverter has a multi-featured control panel with LED, and it is ANSI/PGMA G300 Compliant with CO sensor shutdown.
- Choosing a selection results in a full page refresh.