Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
SUA5000C - 5000 Watt Portable Generator
SUA5000C - 5000 Watt Portable Generator
SKU: SUA5000C
Barcode: 851217006053
Features:
- High Output: 5,000 Starting Watts / 4,250 Running Watts
- AC Outlets: 60Hz, 120VAC / 240VAC, Single Phase
- Performance Series Engine: 223cc / 7.5HP OHV, single cylinder, air-cooled, 4-stroke engine with manual start
- Run Time: 4.0 gallon, large heavy duty all steel construction fuel tank provides up to 9 hours of run time at 50% load
Low Oil Shut Down: Automatically protects engine from potential damage - Heavy Duty Construction: 1.0in. dia. rigid tubular steel frame with attractive silver grey powder coat finish
- Digital Hour Meter: Monitors runtimes and scheduling of maintenance intervals
- Free Shipping
- Free Returns Within 30 days
Couldn't load pickup availability
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
SUA5000C - 5000 Watt Portable Generator
Description:
The A-iPower SUA5000C has 5,000 starting watts with 4,250 running watts to power your tools at the construction site, camping ground, or household appliances. With an easy-pull recoil start, its powerful 223 cc 7.5HP OHV 4 stroke engine comes with a low oil alert light and low oil automatic shutdown to keep your generator performing year after year. The 4-gallon gasoline fuel tank provides an average run time of 9 hours at 50% load. Featuring a fold down handle, the unit has rigid tubular steel frame with attractive silver-grey powder coat finish.
Powerful Performance
Delivers reliable power for home backup, job sites, and outdoor activities. Easily runs essential appliances, tools, and equipment when you need dependable electricity.
High-Performance Engine
Equipped with a durable 223cc Performance Series engine that provides strong output, efficient fuel consumption, and long-lasting performance.
Long Runtime Fuel Tank
The heavy-duty 4-gallon steel fuel tank delivers up to 9 hours of runtime at 50% load, reducing refueling and keeping your power running longer.
Durable & Safe Design
Features a rugged tubular steel frame, digital hour meter for maintenance tracking, and low-oil shutdown to automatically protect the engine from damage.

| SUA5000C SPECIFICATIONS | |
|---|---|
| Model | SUA5000C |
| UPC Code | 851217006053 |
| OUTPUT | |
| Running Watts | 4250W |
| Starting Watts | 5000W |
| AC Load | 120/240 Volts |
| Phase/Frequency | Single / 60Hz |
| Running VAC Amperage | 17.7A |
| Automatic Voltage Regulator | Yes |
| Noise Level: dBA at 23 ft. (7 m) | 68 |
| ENGINE | |
| Engine (OHV) | 223cc / 7.5hp |
| Alternator | Senci |
| Starting Method | Manual |
| Fuel Tank Capacity | 4 Gal. (15L) |
| Run Time @ 50% Load | 9 hours |
| Run Time @ 100% Load | 6 hours |
| Built–in Gauge on Fuel Tank | Yes |
| Engine Oil Capacity | 0.6 Qt. (0.6L) |
| Recommended Oil | SAE 10W-30 |
| Engine Oil Supplied | 0.6Qt. 10W-30 |
| Muffler with USDA Spark Arrestor | Yes |
| Low-Oil Shutdown | Automatic |
| Lubrication Method | Splash |
| CONTROL PANEL | |
| LCD Hour Meter | Yes |
| Direct Circuit (DC) | Yes |
| Low-Oil Alert Lamp | 1 |
| Circuit Breaker | 8.3A, 20A, 30A |
| 120V 20A NEMA Outlet | 2 GFCI |
| 120V 30A NEMA L5–30R Outlet | 1 |
| 120/240V 30A NEMA L14-30R Outlet | 1 |
| Weather Protected Outlet Cover | 3 |
| Neutral Bonded to Frame | Yes |
| CERTIFICATIONS | |
|---|---|
| Emission Certification | EPA / CARB |
| TRANSPORTATION | |
| Durable Tubular Steel Frame | 1.0 in diameter (25 mm) |
| Fold-Down Handle | Factory Built-in |
| Wheel Kits | 7-in. solid wheel |
| PACKAGING | |
| Gross Weight | 130 Lbs / 59 kgs |
| Net Weight | 123 Lbs / 54 kgs |
| Assembly Dimension | 24.4 x 22.8 x 22.6 in |
| Packing Dimension | 25.4 x 19 x 21.6 in |
| Loading Q'ty (20GP/40GP) | 164 / 336 |
| Included Accessories | DC Charging Cable - RV Adaptor - Spark Plug Socket |
| GENERAL | |
| Warranty | 2-Year Residential / 1-Year Commercial |
Unboxing & Operation Video
Maintenance Video
Video content is being prepared and will be updated soon.
Stay tuned for more exciting content!
Safety Q&A
1、Where should I place the generator during operation?
Always operate the generator outdoors only. Keep it at least 20 feet (6 m) away from doors, windows, and vents, and at least 5 feet (1.5 m) away from any combustible materials. Place it on a dry, stable surface under a protective cover or canopy to shield it from the weather.
2、What should I know before refueling a generator?
Always turn off the generator and let it cool down completely before refueling.
Use clean, fresh fuel of the recommended grade.
Never refuel while the generator is running or hot, as this may cause fire or explosion.
3、Where should I safely store a generator when not in use?
Store the generator in a cool, dry, and well-ventilated location. Make sure the air vents are not blocked and that it is kept away from any flammable materials.
4、How do I safely transport a generator?
Before transporting, turn off the unit, drain the fuel tank, and disconnect the spark plug. Keep the generator upright during transport, ensure ventilation openings are not blocked, and avoid exposure to heat or moisture.
Setup/Startup
1、How do I connect the generator battery? (For models with electric start)
When you first receive the generator, the negative battery cable is usually disconnected to prevent discharge during storage.
- Locate the negative cable near the top or rear of the battery.
- Attach the loose end of the negative cable to the negative terminal post of the battery and tighten securely with a bolt.
- ⚠ Caution: Avoid touching both the battery terminal and the generator frame with tools or metal objects at the same time to prevent short circuits.
2、What type of engine oil should I use?
Initial use (break-in period): SAE 30, 10W-30, or 5W-30 mineral oil is recommended.
After break-in: You may use either mineral oil or full synthetic oil.
High temperatures (above 95°F / 35°C): 10W-40 is recommended.
3、What type of gasoline should I use?
Use unleaded gasoline with an octane rating of 87 or higher, and with ethanol content of no more than 10% (E10).
⚠ Tip: Lower ethanol content helps extend the life of the carburetor, fuel system, and seals.
4、How do I add fuel and check the oil for the first time?
Before the first startup, fill with the recommended engine oil.
Check the dipstick and ensure the oil level is within the marked range.
When adding oil or fuel, avoid spills, keep away from open flames, and use a dedicated oil/fuel container for safety.
5、How do I start the generator with recoil (pull) start? - Set the breaker and master control switch to OFF.
- Select the fuel type:
Gasoline: Open the gasoline valve → Turn the fuel selector to Gasoline.
Propane: Close the gasoline valve → Turn the fuel selector to Propane → Connect the propane tank and open the valve. - Switch the battery to ON (or “RUN” on some models).
- Pull the recoil cord: Pull slowly until resistance is felt, then pull sharply. Repeat if necessary until the engine starts
6、How do I use the electric start function?
Ensure the battery is properly connected and charged.
Set the fuel switch to the correct position.Turn the start switch to START.
Once the engine starts, release the switch and let it return to RUN/ON.
7、Does the generator need to warm up?
Yes. After starting, let the engine run idle for 1–3 minutes to allow the oil to circulate fully before applying a load.
8、How do I safely connect electrical loads?
Start the generator before connecting any appliances.
Connect higher-wattage devices first (e.g., refrigerator, air conditioner), then smaller devices.
Do not exceed the rated wattage capacity of the generator.
9、How do I start the generator in cold weather?
Use engine oil suitable for low temperatures (e.g., 5W-30).Place the generator in a warmer environment or use an engine block heater if available.Expect longer starting times in freezing conditions — this is normal.tent goes here.
Maintenance
1、How do I change the generator oil?
- Place the generator on a level surface.
- Locate the oil drain bolt at the bottom lip of the crankcase and place a container underneath.
- Use a 12mm wrench to remove the drain bolt and allow the oil to drain completely.
- Reinstall the bolt, remove the oil filler cap, and refill with oil until it reaches the thread level of the cap.
Tip: If the generator is on a flat surface, excess oil will naturally overflow before it is overfilled.
2、How do I drain fuel from the tank? - Turn the fuel valve to the OFF position.
- Place a container under the fuel 3. filter cup (below the valve).
- Remove the cup and turn the valve to ON to drain fuel completely.
Reinstall the fuel filter cup.
3、How should I prepare my generator for long-term storage?
Turn the circuit breaker OFF and run the generator for 3–5 minutes.
Switch the fuel valve to OFF and let the engine run until it shuts down.
Turn the engine/battery switch to OFF.
Drain remaining fuel from the tank and carburetor.
Remove the spark plug, add 2 tablespoons of 10W-30 oil into the cylinder, and pull the recoil starter a few times to lubricate.Reinstall the plug.
Disconnect and remove the battery, then maintain it with a trickle charger.
Store the generator in a cool, dry, and well-ventilated location.
4、How do I maintain the generator battery?
Generator batteries can lose charge within 3–6 months of storage.
Disconnect the battery when not in use.
Use a 12V SLA-compatible trickle charger to keep it charged.
Avoid exposing the battery to extreme heat or cold.
5、How often should I perform generator maintenance?
Before each use: Check fuel level, engine oil, and air filter. Every 50–100 hours of operation: Change engine oil, clean the spark plug, and service the air filter. Long-term storage: Drain fuel completely and store the generator properly.
6、Do I need to replace the air filter, and how often?
Yes. The air filter should be cleaned every 25 hours of use and replaced every 100–150 hours, or more often in dusty conditions.
7、When should I replace the spark plug?
Inspect the spark plug every 100 hours of operation. Replace it if it shows wear, buildup, or damage.
8、How do I prevent stale fuel from damaging the engine?
If the generator will not be used for more than 30 days, add a fuel stabilizer to fresh gasoline or drain the fuel system completely.
How to Contact Us for Further Assistance:
Phone Support: Connect directly with our knowledgeable customer service team at 855-888-3598 for immediate assistance.
Email Support: Send us an email with your inquiry, and our support team will respond promptly.
Live Chat: Use our real-time chat feature to get instant answers to your questions.
SUA5000C Manual
SUA5000C Spec Sheet
SUA5000C Quick Start Guide
-
-
-
-
-
No reviews found
No questions found
Your cart
(0)
Your cart is currently empty.
Not sure where to start? Try these collections:
Order note
Estimate Shipping
Coupon
Product Comparison
| Description |
| Price |
| Vendor |
| Type |
| Running Watts |
| Starting Watts |
| Run Time |
| Noise Level |
| Start Type |
| Regular price
$450.96
Sale price
$450.96
Regular price
Unit price
/per
| A-iPower Corp. | Open-frame generator | 4250 | 5000 | 12 | 68 | Recoil |
Choose your option
SUA5000C - 5000 Watt Portable Generator
SUA5000C - 5000 Watt Portable Generator
Vendor: A-iPower Corp.
Type: Open-frame generator
- Modern
- Eco-certified
- Warranty
Hurry up, only 20 items left in stock.
- Choosing a selection results in a full page refresh.
- Opens in a new window.